Ultrasound Scanner Portable Electronic Convex Digital WED 9618

R55 709,90

Add R2 000,00 to cart and get free shipping!

Ultrasound Scanner Portable Electronic Convexdigital WED 9618

TECHNICAL SPECIFICATIONS:  

Application range
This device is suitable in hospitals and clinics for diagnosing liver, GB, spleen, kidney, pancreas, heart, bladder, and uterus.Feature set
This device uses micro computer technology, Digital Scanning Converter (DSC), variable aperture, multi-section dynamic focusing, high dynamic low noise and wide band pre-amplifier, log compression, TGC control, dynamic filtering, edge enhancement and frame correlation. The embedded components allow a clear, stable and high resolution image.
� Front End with 80 arrays, 20 channels
� Display modes: B, B+B, B+M, M; Gray scales: 256 levels.
� Real time scanning or picture freezing for analysis.
� Image amplification, black-white reversed, up/down conversed and shift depth in Real Time.
� Soft-touching keyboard and track ball to make operation faster, convenient and flexible.
� Video connector, outputting PAL-D standard that can be easily connected to large external monitor, VCR or image printer.
� Portable structured with plastic cover. The use of switch power supply, integrate circuits (FPGA) and Surface Mounting Technology (SMT) makes this device portable with a small volume and light weight.
� This device has passed clinical verifications of safety and diagnosis validity.Technical Specification
� Standard probe : 3.5MHz Triple frequency Electronically convex
� Optional probe :
1, L40/7.5MHz Linear Probe
2, L40/7.5MHz EndoRectal Linear
3, R13/6.5MHz Transvaginal Convex Probe
� Scanning depth : 200mm
� Acoustic Power Mode M (C1-2/R60) :- P- : 1.0498mpa
– Iob 1.316mw/cm2
– Ispta 2.63mw/cm2
� Lateral resolution : ≤ 3mm (depth≤ 80mm) or ≤ 4mm (80mm < depth≤ 130mm)
� Axial resolution : ≤ 2mm (depth ≤ 80mm) or ≤ 3mm (80mm < depth≤ 130mm)
� Dead zone : ≤ 5mm
� Geometric position precision (%) :

– Horizontal : ≤ 15
– Vertical : ≤ 10
� Monitor screen : 10″ non interlaced, pseudo color processor (see below available options)
� Display mode : B, B+B, B+M, M
� Image gray scale : 256 levels
� Electronically focusing : 4 focus combinations
� Image magnification : �1.0, �1.2, �1.5, �2.0
� Zoom : �2
� Cine-loop : 412 frames included as standard
� Permanent storage : 32 frames
� Pseudo color unit : Included.
� Image reverse : Left/Right, Up/Down, Black/White
� Depth shift : B, B+B modes real time shift
� Frame correlation : B, B+B modes 3 levels
� Measurement functions :
– B mode: Distance, circumference, area, heart rate, pregnant, Week, fetal weight, EDD
– M mode: Heart rate, time, EF
� Charactere input/display : date, patient�s ID, age, sex
� Body marks : 10 types
� Power consumption : 70VA
� Dimensions (L�W�H): 353mm � 315mm � 253mm

Environment requirements
� Temperature : +5°C~+40°C
� Humidity : <80%
� Atmospheric pressure : 70kpa~106kpa
� Power supply : AC/DC Adapter/Charger 110/220V AC ±11/±22V 50/60Hz, Output: DC 10-12V

Description

Ultrasound Scanner Portable Electronic Convexdigital WED 9618

TECHNICAL SPECIFICATIONS:

 

Application range
This device is suitable in hospitals and clinics for diagnosing liver, GB, spleen, kidney, pancreas, heart, bladder, and uterus.

Feature set
This device uses micro computer technology, Digital Scanning Converter (DSC), variable aperture, multi-section dynamic focusing, high dynamic low noise and wide band pre-amplifier, log compression, TGC control, dynamic filtering, edge enhancement and frame correlation. The embedded components allow a clear, stable and high resolution image.
� Front End with 80 arrays, 20 channels
� Display modes: B, B+B, B+M, M; Gray scales: 256 levels.
� Real time scanning or picture freezing for analysis.
� Image amplification, black-white reversed, up/down conversed and shift depth in Real Time.
� Soft-touching keyboard and track ball to make operation faster, convenient and flexible.
� Video connector, outputting PAL-D standard that can be easily connected to large external monitor, VCR or image printer.
� Portable structured with plastic cover. The use of switch power supply, integrate circuits (FPGA) and Surface Mounting Technology (SMT) makes this device portable with a small volume and light weight.
� This device has passed clinical verifications of safety and diagnosis validity.

Technical Specification
� Standard probe : 3.5MHz Triple frequency Electronically convex
� Optional probe :
1, L40/7.5MHz Linear Probe
2, L40/7.5MHz EndoRectal Linear
3, R13/6.5MHz Transvaginal Convex Probe
� Scanning depth : 200mm
� Acoustic Power Mode M (C1-2/R60) :

– P- : 1.0498mpa
– Iob 1.316mw/cm2
– Ispta 2.63mw/cm2
� Lateral resolution : ≤ 3mm (depth≤ 80mm) or ≤ 4mm (80mm < depth≤ 130mm)
� Axial resolution : ≤ 2mm (depth ≤ 80mm) or ≤ 3mm (80mm < depth≤ 130mm)
� Dead zone : ≤ 5mm
� Geometric position precision (%) :

– Horizontal : ≤ 15
– Vertical : ≤ 10
� Monitor screen : 10″ non interlaced, pseudo color processor (see below available options)
� Display mode : B, B+B, B+M, M
� Image gray scale : 256 levels
� Electronically focusing : 4 focus combinations
� Image magnification : �1.0, �1.2, �1.5, �2.0
� Zoom : �2
� Cine-loop : 412 frames included as standard
� Permanent storage : 32 frames
� Pseudo color unit : Included.
� Image reverse : Left/Right, Up/Down, Black/White
� Depth shift : B, B+B modes real time shift
� Frame correlation : B, B+B modes 3 levels
� Measurement functions :
– B mode: Distance, circumference, area, heart rate, pregnant, Week, fetal weight, EDD
– M mode: Heart rate, time, EF
� Charactere input/display : date, patient�s ID, age, sex
� Body marks : 10 types
� Power consumption : 70VA
� Dimensions (L�W�H): 353mm � 315mm � 253mm

 

Environment requirements
� Temperature : +5°C~+40°C
� Humidity : <80%
� Atmospheric pressure : 70kpa~106kpa
� Power supply : AC/DC Adapter/Charger 110/220V AC ±11/±22V 50/60Hz, Output: DC 10-12V

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Ultrasound Scanner Portable Electronic Convex Digital WED 9618”